Power sequencer

The power sequencer can start the power supply one by one from the front-end equipment to the back-end equipment, and when the power supply is turned off, all types of electrical equipment can be turned off in order from the back-end to the front-end. This can effectively manage and control all types of electrical equipment, avoid human error operations, reduce the impact of electrical equipment on the power grid at the moment of switching, and avoid the impact of induced current on the equipmen

8-way controllable power manager (network version with timing) PS-8NET

  • 8-way controllable power manager (network version with timing) PS-8NET

PRODUCT

1. Power Manager is a compact and powerful intelligent power manager with ARM Cortex-M0 core processor, which integrates power sequencer and timer functions into one

2. Supports TCP/IP control, PC management software can achieve multi device joint debugging, and monitor device status; Support iOS Android app control; Simultaneously equipped with RS-485 interface and supporting multi device cascading control, devices can be set and managed through the central control device

3. Built in 1, 2, 8, 6, 4 intelligent display windows can display real-time parameters such as current voltage, date, time, weekly schedule, channel switch status, etc

4.8 switch channel outputs, each start delay and stop delay time can be freely set (start: start on, 1-240 seconds, never open; stop: stop off, 1-240 seconds, never close)

5. Built in clock chip, real-time display of current date and time, and implementation of timed on/off function

6. Weekly plan management, today's plan management. Can temporarily cancel or increase the start time period for today

7.8 sets of device switch scenarios save and call, which can be applied to different occasions

8. Undervoltage and overvoltage detection protection and alarm

9. Operating voltage:~220V 50Hz

10. Power output: 8 controllable channels, one direct output

11. Start delay: On immediately, 1 to 2 40 seconds, never on

12. Stop delay: Stop and close, 1 to 2 4 0 seconds, never close

13. Maximum current: 30A@220V 50Hz

14. Display content: time, status of each circuit, voltage, plan, today's plan

15. Display method: 1, 2, 8, 6, 4 dot matrix display screen, LED

16. Single circuit current: 20A

17. Protection range: Under voltage 1700 to 190V, over voltage 2400 to 2600V adjustable

18. Timing method: Within a week, 8 time periods can be set on any day

19. Scenario modes: 8 adjustable

20. Language: Simplified Chinese/English


Copyright LBT © 2022 www.lbtint.com All Rights Reserved. | 沪ICP备18014772号-2